UPS, Power Backup & Cooling in Ethiopia

Keep servers, networks and branches running through every outage, with power and cooling sized, installed and maintained by one team.

UPS, Power Backup & Cooling in Ethiopia

Uninterruptible Power Supply (UPS) and Cooling in Ethiopia

360Ground supplies, installs and maintains power and cooling for Ethiopian server rooms, data centres and branches. We deliver uninterruptible power supply (UPS) systems, from rack units to room-level online double-conversion UPS, together with battery banks, power distribution units (PDUs), automatic transfer switches (ATS), precision cooling, standby generators and environmental monitoring. Brands include APC by Schneider Electric and Vertiv, sourced through authorised channels with genuine manufacturer warranty and local support. Because the same team specifies your servers, storage and network, every system is sized to the real IT load and runtime you need, then maintained under one contract with the equipment it protects.
CRM Software in Ethiopia for Sales Teams – overview

Top Organizations Trust 360Ground

DStv Ethiopia logo
Awash Bank logo
zemen bank Web Design & Development
Amole logo
Ethiopian Securities Exchange
Ministry of Health Ethiopia logo

Our Offerings

Rack & Room UPS

UPS Batteries & Replacement

PDUs & Transfer Switches

Precision Cooling

Standby Generators

Environmental Monitoring

Sizing & Site Survey

Installation & Commissioning

SLA Maintenance & Spares

Why 360Ground ?

Tell us about your server room, racks and outage pattern. We will size the UPS, batteries and cooling and send a birr quote.

Case Studies

Every project is a journey, and we measure success by the results our clients achieve. From MVPs that disrupt industries to enterprise solutions that scale globally, these stories show how we transform ideas into market-leading solutions.

Questions? Answers.

1. What size UPS do I need for a server rack?

Start by adding up the real power draw of everything in the rack in watts, including servers, storage and network switches. Add headroom of around 20 to 30 percent for growth, then choose a UPS whose watt rating, not just its VA rating, covers that load. Finally, decide how many minutes of runtime you need, which sets the battery size. We run this load audit and calculation for you as part of the site survey.
There is no single answer. Runtime depends on how heavily the UPS is loaded and on the size, age and temperature of its batteries. A 10 kVA UPS running close to full load on internal batteries may last only a few minutes, while the same unit at half load with external battery packs can run far longer. Tell us your load and the runtime you need, and we will size the battery bank to match.
Most UPS systems, including APC by Schneider Electric and Vertiv models, use sealed lead-acid batteries that typically need replacing every three to five years. They wear out faster in hot rooms, with frequent outages and deep discharges, which are common in many Ethiopian sites. Regular testing shows when capacity is dropping before a battery fails during a power cut. Our maintenance plans include scheduled battery testing, replacement and safe disposal.
A line-interactive UPS passes mains power through, corrects small voltage changes and switches to battery when power fails, with a very short transfer. It suits desktops, small offices and network cabinets. An online double-conversion UPS converts all incoming power and rebuilds a clean output continuously, so there is no transfer at all. It is the standard choice for servers, data centres and sites where the grid voltage is unstable.
A split air conditioner can work for a small comms room with a few kilowatts of load, but it is designed for people, not equipment. Server rooms produce steady heat all day and night and need tight control of temperature and humidity. Precision cooling is built to run continuously, controls humidity and supports redundancy. We assess your heat load and room layout, then recommend the right cooling and backup arrangement.
Yes. SLA maintenance, spares and secure disposal come with the hardware we supply. Maintenance plans cover scheduled inspections of UPS units, batteries, PDUs, transfer switches and cooling, battery load testing and replacement, firmware updates, warranty registration and escalation to the manufacturer. Because your power, cooling and IT equipment sit under one contract, there is no disagreement between suppliers about who fixes what when something fails.
Use layers of protection. An online UPS keeps equipment running and clean-powered through short outages. A standby generator with an automatic transfer switch covers longer ones, and the UPS bridges the changeover. Precision cooling keeps temperature and humidity stable, and environmental monitoring warns your team about heat, leaks or open doors. We design these layers together so each is sized to your IT load and the runtime you need.
Yes. We respond to tenders for the supply, installation and commissioning of uninterruptible power supply (UPS), precision cooling and related power equipment for server rooms and data centres, and to annual maintenance contracts for UPS and cooling. We prepare the load calculations, technical specifications, bill of materials and birr pricing. Share the tender reference and site details, and we will arrange a site survey where needed.

Get a Power & Cooling Assessment

Tell us about your server room, racks and outage pattern. We will size the UPS, batteries and cooling and send a birr quote.